Ultrasonic scalpel

caca

An ultrasonic surgical device (ultrasonic scalpel) is a piece of clinical surgical equipment that uses ultrasonic energy for hemostatic dissection and coagulation of soft tissue. It can be used to cut soft tissues other than bone and fallopian tubes, and to cut and seal vessels up to 7 mm in diameter. It is widely used in various open and endoscopic surgeries.
Compared with traditional hand-held devices or devices powered by other energy sources, the ultrasonic scalpel provides greater precision, less smoke output, and no electrical current passing through patients' bodies, resulting in greater safety for patients and greater convenience for surgeons.
The working principle of ultrasonic scalpel is that the blade of ultrasonic scalpel is mechanically vibrated at the ultrasonic frequency of 55.5 kHz, then the water molecules in the tissue are evaporated, the hydrogen bond of the protein is broken, the cells are disintegrated, so that the tissue is cut or coagulated.

Compared with high-frequency electrosurgical knife, lancet and hemostat, ultrasonic scalpel has the following advantages:
1. Ultrasonic scalpel performs various functions of vessel coagulation, clamping, separation and other surgical operations. When using an ultrasonic scalpel, surgeons do not need to change equipment during the operation, which simplifies the operation and reduces operating time;
2. When the ultrasonic scalpel works, it does not emit smoke, and the vision of the operation is clear;
3. The tissue temperature is below 100℃ when operating the ultrasonic scalpel, and the lateral thermal damage range is within 1mm;
4. The principle of ultrasonic scalpel sealing blood vessels is to denature and coagulate proteins, the blade and tissue will not stick together, which will not cause scab tearing off and will not cause bleeding, so as to reduce the risk of infection, bleeding and post-operative drainage, promote wound healing. Ultrasonic scalpel is the first choice for minimally invasive surgery due to its irreplaceable performance advantages.
Ultrasonic scalpel is widely used in surgery, such as gastrointestinal reconstruction and hepatobiliary resection in general surgery, tumor resection and lymph node dissection in breast surgery, kidney resection in urology, etc., ultrasonic scalpel has outstanding performance advantage, which can increase the safety and effectiveness of the operation, as well as improve the quality of life of patients after surgery.

Higher cutting speed
The average dissection speed of SoniCure™ is 3.87 seconds, while the world famous J Brand ultrasonic scalpel has an average dissection speed of 4.25 seconds. The data were obtained from a comparison of ex vivo dissection experiments of porcine small intestine with 30 specimens each. Experimental results show that there is no statistical difference in dissection speed between SoniCure™ ultrasonic scalpel and top-notch international brands.

Reliable sealing of vessels
SoniCure™ SC100E has a special energy control algorithm for vascular tissue. Thanks to precise energy control and appropriate jaw pressure, excellent and reliable vascular closure is achieved. The burst pressure test was adopted for the leak-tightness of the vessel. Experimental results showed that the burst pressure of SoniCure™ was higher than that of the J Group brand, regardless of whether the artery or vein was ≥ 3 mm or between 2-3 mm. All burst pressure values exceed 1100 mmHg. Art., which is more than 8 times the normal systolic pressure of the human heart.

Less thermal damage
The range of thermal damage was measured by histopathological evaluation method, and the distance from the point of tissue degeneration furthest from the cutting edge to the cutting edge was measured, and the results of typical cases are shown in the figure below. Experimental results show that the thermal damage range of SoniCure™ SC100E in sealing blood vessels and dissecting liver tissue is less than 1 mm, which meets the requirements of clinical application.

The SoniCure™ SC100E ultrasonic scalpel system consists of an ultrasonic generator, an ultrasonic transducer, an ultrasonic scalpel, and an additional device foot switch.

Generator
Power level
MAX. power level 4-5
MIN. power level 1-4
Default: max. 5 minutes. 3
Size L: 40 cm, W: 40 cm, H: 12 cm
Weight 6.65 kg
Frequency 55.5 kHz ± 1 kHz

LED display showing status clearly
Connection status display
Power level display
Error code display
Displaying the sensor usage time when connecting the sensor to the generator

Easily customizable options
Adjust the maximum/minimum power level by pressing the “+-” button.
Adjust the volume by pressing "T" and "+", or "T" and "-".

Precise Energy Control Technology
Featuring an advanced energy management algorithm, the SoniCure™ Generator adjusts power output in real time according to changes in tissue conditions, providing optimal dissection and sealing effect with minimal thermal damage.

Intelligent cut detection technology
The SoniCure™ generator has a pre-assessment function for tissue cutting. When the cut is near completion, the generator can change the frequency of the tone, which prompts the operator to open the jaw. This will reduce wear on the jaw gasket and increase the efficiency of the operation.

Lightweight and simple operating system
The intuitive LED display makes system setup more convenient. Comprehensive self-testing and system monitoring functions.

Ultrasonic scalpel
Rod length 13cm, 21cm, 35cm, 43cm
Rod diameter 5.5 mm
Curved shape
MIN/MAX power level
MAX. power level 4–5
MIN. power level 1-4
Frequency 55.5 kHz ± 1 kHz
Vibration amplitude less than 100 microns
High quality titanium alloy ensures efficient energy transfer.
Wear-resistant jaw gasket can withstand more than 5,000 openings.
Strong clamping force ensures a secure grip on the fabric.
Integral molding of the curved blade is resistant to breakage.
Integrated torque wrench design with rotary wheel.
Ergonomic design.
Simplified installation.
Four rod lengths meet the needs of different surgical procedures.

Sensor
High quality piezoelectric ceramic material ensures efficient energy conversion
Autoclavable
Built-in memory chip to record usage time
Usage time: 99

Address:
100077, UZBEKISTAN REPUBLIC, TASHKENT C., MIRZO-ULUGBEK DSTR., CHUST STR. 9/17
Phone number:
Оставить заявку
Indicates required fields
Ваше имя*
Indicates required fields
Телефон:*
Indicates required fields
Комментарий*
Indicates required fields
Галочка*
Спасибо! Форма отправлена