I. Configurations:
Hardware:
Name Model Brand Quantity
X-ray system generator CTHVG X5001 WDM 1
X-ray tube XRC-5552X CANON 1
Collimator CTXS-3B WDM 1
Imaging System WD-CT Imaging Software Acquire WDM 1
Detector WDDAS-2B WDM 1
24" WDM Color LCD Monitor 1
Workstation CT server Advantech 1
Other equipment Portal SMJ-2 WDM 1
Patient table SMC-2A WDM 1
TT console CTBOX-2 WDM 1
Power distribution PSB-30 WDM 1
Optional:
No. Description Quantity
1 Portal inclined SMJ-1 1
2 Table height SMC-1 1
3 Advanced Clinical Diagnostic Package CT Vascular Analysis (SC6015) 1
CT Perfusion Analysis (SC2011) 1
CT Spine Extraction and Analysis (SC1401) 1
CT rib analysis (SC1402) 1
Colon CT Analysis (SC5003) 1
CT analysis of lung vesicles (SC6008) 1
CT reconstruction of dental panorama (SC5002) 1
II. Data sheet:
Detector Scintillator material GOS rare earth ceramics
Physics series number 32
Number of detection blocks in a row 736
Tube and generator Anodic target surface Rhenium Tungsten alloy
Heat capacity of the tube 5MHU
Tube cooling method Oil cooling and wind cooling
High voltage generator power 50 kW.
Optional tube voltage range: 70 kV, 80 kV, 100 kV, 120 kV, 140 kV.
Maximum tube output current 420 mA
The minimum output current of the tube is 10 mA.
Focus tube (Small, Large) 0.9mm×0.7mm
1.4 mm × 1.4 mm
Gantry Type Slip Ring Low Voltage Slip Ring
Drive path Leather drive belt
Data transmission mode Radio frequency and optical fiber
Scanning frame aperture 700 mm.
Digital scanning frame angle Digital ±30°
The portal system can be controlled remotely. Yes.
3D laser positioning system Yes
Portal cooling mode Wind cooling
Portal control panel Yes
Graphic prompts for breathing control Yes
Voice prompts for breathing control Yes
Table Maximum travel range 2100 mm
Maximum scanning range per helix 1620 mm (optional 1750 mm)
Check the bed positioning accuracy ±0.25mm.
Foot switch table control Yes
The maximum load-bearing capacity of the table is 210 kg.
Table movement control Manual and motorized
Scan parameters Scan layer/360° 64-layer image/360°
Fastest scan time /360° 0.49 s/360°
The thickness of the thin image scanning layer is 0.5 mm.
The thinnest image reconstruction layer is 0.5 mm thick.
Step range 0.15-2.0
Free field selection Yes
Scan mode Positioning, axial, spiral
Spiral Pattern Normal and Oblique
Image acquisition matrix 512×512, 768×768, 1024×1024
Image reconstruction matrix 512×512,768×768,1024×1024
Image display matrix 512×512, 768×768, 1024×1024
Scanning time for one spiral 100 s
Spatial resolution 18LP/CM
Density resolution 2 mm at 0.3%
Integrated workstation
(Shooting + post-processing)
Workstation Advantech CT Server
Display screen size 24 inches
Memory 32 GB
Hard drive 2T.
CPU
Processor 6 cores
Image format and transmission storage: DICOM 3.0 standard Yes
Image storage capacity (512×512) ≥800,000
Image transfer rate from host to workstation (fps) 50 fps
Automatic voice system and two-way voice Yes
Synchronous Parallel Image Processing Function Yes
Remote Control Service Diagnostic Interface Yes
DICOM3.0 interface for laser camera Yes
Report module Yes
Print module Yes
Clinical diagnostic software:
Low dose lung scanning technology Yes
Low dose pediatric scanning technology Yes
Intelligent tube current automatic control technology Yes
Iterative noise reduction method Yes
Radiation hardness artifact correction software Yes
Posterior fossa image optimization Yes
Motion Artifact Removal Technology Yes
Metal Artifact Removal Technique Yes
Maximum Projection Density MIP Yes
Minimum Density Projection MinIP Yes
Average Density Forecast AIP Yes
Intervertebral disc reconstruction module Yes
Print module Yes
Automatic typing and printing Yes
DICOM features include DICOM PRINT, DICOM STORE, DIOCM QUERY, DICOM RETRIVE, WORKLIST and PPS Yes.
Connection to existing his.ris equipment Yes